• 3000GPD Seawater Reverse Osmosis Desalination Plant
  • 3000GPD Seawater Reverse Osmosis Desalination Plant
  • 3000GPD Seawater Reverse Osmosis Desalination Plant
  • 3000GPD Seawater Reverse Osmosis Desalination Plant
3000GPD Seawater Reverse Osmosis Desalination Plant

3000GPD Seawater Reverse Osmosis Desalination Plant

Product Details:

Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE/NSF etc.
Model Number: SM-3,000GPD~7,000GPD

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Export Wood Crate/Carton or Naked wrapped by film
Delivery Time: 15~30 days
Payment Terms: T/T, Western Union, Paypal etc.
Supply Ability: 50 set per month
Get Best Price Contact Now

Detail Information

Technology: Reverse Osmosis Design: Skid Mount
Recovery Rate: 27~48% Feed TDS/ppm: <42,000
Water Temp.: 5~35˚C PH: 4~9
TSS/mg/L: <5 Silt Density Index: <3
Free Chlorine Mg/L: 0 Dissolved Iron Mg/L: <0.1
Warranty: 1 Year Material: SS304/SS316L,carbon Steel
Voltage: 380V,415V,220V,can Be Customized Application: Water Purification,Filtration,pharmceutical,drinking Water,food
Size: Depends,1750*550*1650mm Type: Seawater Reverse Osmosis System
Function: Water Purifying, Desalination Desalination Rate: 99%,99.7%
Control: Electronic,Manual/PLC Ro Membrane: Hydranautics Or DOW,4040
Pump: Danfoss/CAT/CNP
High Light:

3000GPD seawater reverse osmosis desalination plant

,

OEM seawater reverse osmosis desalination plant

,

3000GPD reverse osmosis desalination system

Product Description

3000GPD Seawater Reverse Osmosis Desalination Plant

SM series Seawater Reverse Osmosis Desalination System 3,000GPD~7,000GPD

SM – Series Reverse Osmosis Systems are designed and manufactured for seawater applications requiring capacities of 3,000 to 7,000 gallons per day.

SM – Series Reverse Osmosis Systems are equipped with premium components, which include a 316L plunger–type pump for high performance and corrosion resistance, a high grade corrosion resistant aluminum frame, a programmable computer controller with many built–in features and fiberglass membrane housings for durability.

 

Features

Micro-computer Controller

LCD Backlit Display

Pre–Treatment Lockout

Tank Level Input

Low and High Pressure Monitoring and Alarm

Permeate TDS Monitoring

Hour Meter

Feed Flush

High Rejection Sea Water Membranes

FRP – Series Membrane Housings

5 – Micron Sediment Pre–Filter

by Pentek® Single O–Ring Cartridge Housing

Permeate and Concentrate Flow Meters

Motorized Valve PVC

0 – 100 psi Pre–Filter Out Pressure Gauge

0 – 1500 psi Concentrate Pressure Gauge

316L Stainless Steel Needle Valve

SS Feed Low Pressure Switch

SS Pump High Pressure Switch

Pressure Relief Valve

Pressure Regulator

316L High Pressure Pump

TEFC Motor with Thermal Motor Protection

White Powder Coated Aluminum Frame

High Pressure 316L Stainless Steel Tubing and Fittings

High Pressure Hose with Reusable SS Fittings

 

Technical Specifications

Models SM – 4140 SM – 5140 SM – 6140
Design
Configuration Single Pass Single Pass Single Pass
Feedwater Source† <45,000 ppm <45,000 ppm <45,000 ppm
System Recovery with Recycle % 27 – 48 27 – 48 27 – 48
Rejection and Flow Rates†††
Nominal Salt Rejection % 99.4 99.4 99.4
Permeate Flow Rate (gpm / lpm) 2.70 / 10.22 3.47 / 13.13 4.80 / 18.17
Concentrate Flow Rate (minimum) (gpm / lpm) 4.00 / 15.00 4.00 / 15.00 4.00 / 15.00
Connections
Feed Connection (in) 1 FNPT 1 FNPT 1 FNPT
Permeate Connection (in) 1 FNPT 1 FNPT 1 FNPT
Concentrate Connection (in) 1 FNPT 1 FNPT 1 FNPT
Membranes
Membrane(s) Per Vessel 1 1 1
Membrane Quantity 4 5 6
Membrane Size 4040 4040 4040
Vessels
Vessel Array 1:1:1:1 1:1:1:1:1 1:1:1:1:1:1
Vessel Quantity 4 5 6
Pumps
Pump Type Piston Piston Piston
Motor HP 7.5 7.5 7.5
RPM at 60Hz 3600 3600 3600
System Electrical
Controller S – 150 S – 150 S – 150
High Voltage Service + Amp Draw 220V, 3PH, 60Hz, 20A** 220V, 3PH, 60Hz, 20A** 220V, 3PH, 60Hz, 20A**
Systems Dimensions
Approximate Dimensions* L x W x H (in / cm) 60 x 26 x 48.5 /
152.4 x 66.0 x 123.2
60 x 26 x 48.5 /
152.4 x 66.0 x 123.2
60 x 26 x 48.5 /
152.4 x 66.0 x 123.2
Approximate Weight (lbs / kg) 270 / 122.47 300 / 136.08 330 / 149.68

Test Parameters: 35,000 TDS Filtered (5 – Micron), Dechlorinated, Municipal Feedwater, 65 psi / 4.50 bar Feed Pressure, 950 psi / 65.5 bar Operating Pressure, 77ªF / 25ªC, Recovery as stated, 7.0 pH. Data taken after 60 minutes of operation.

* Does not include operating space requirements.

** Varies with motor manufacturer.

 

Operating Limits

Design Temperature (°F / °C) 77 / 25 Maximum Turbidity (NTU) 1
Maximum Feed Temperature (°F / °C) 85 / 29 Maximum Free Chlorine (ppm) 0
Minimum Feed Temperature (°F / °C) 40 / 4 Maximum TDS (ppm) < 45,000
Maximum Ambient Temperature (°F / °C) 120 / 49 Maximum Hardness (gpg) 1
Minimum Ambient Temperature (°F / °C) 40 / 4 Maximum pH (Continuous) 11
Maximum Feed Pressure (psi / bar) 65 / 4 Minimum pH (Continuous) 2
Minimum Feed Pressure (psi / bar) 45 / 3 Maximum pH (Cleaning 30 Minutes) 13
Maximum Operating Pressure (psi / bar) 1,000 / 69 Minimum pH (Cleaning 30 Minutes) 1
Maximum Feed Silt Density Index (SDI) <3    

Low temperatures and feedwater quality, such as high TDS levels will significantly affect the systems production capabilities and performance. Computer projections must be run for individual applications which do not meet or exceed minimum and maximum operating limits for such conditions.

System pressure is variable due to water conditions. Permeate flow will increase at a higher temperature and will decrease at a lower temperature.

Product flow and maximum recovery rates are based on feedwater conditions as stated above. Do not exceed recommended permeate flow.

 

3000GPD Seawater Reverse Osmosis Desalination Plant 0

More information about SWRO

What is seawater reverse osmosis?

Seawater reverse osmosis systems are designed to decline more than 99% of saline compromised within the feed water. These systems also incorporate a rinsing, chemical purifying apparatus to eliminate sodium chloride, avert scaling, and preserve system performance. There are two fundamental elements within every seawater reverse osmosis system, which are reverse osmosis membranes and high pressure feed pumps. These elements make up the center of any reverse osmosis system and need special consideration and application for successful operation.

 

Does reverse osmosis remove salt from seawater?

Yes, semipermeable membranes enable the feed water to pass through it at a much higher volume than dissolved salts. Reverse osmosis systems work by applying pressure as freshwater streams through its membranes to filter out the concentrated saline in the feed water, as well as minerals and pollutants. These unwanted impurities are either flushed away, recycled, or processed. Seawater reverse osmosis systems utilize more than one membrane to boost the load of purified water turned out each day.

 

What are the advantages of desalination plants?

Seawater desalination has become a vital alternative to the production of pure freshwater throughout the areas of the world without drinkable water. As other sources such as rivers, lakes, wells, and springs have become more exhausted due to excessive extraction, the ocean has provided an abundant supply of available water for human use. Although ocean water consists of elevated levels of salt, and therefore is unable to be utilized for consumption or most other purposes, seawater desalination has helped make it practical.

 

Want to Know more details about this product
I am interested in 3000GPD Seawater Reverse Osmosis Desalination Plant could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.