• 4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control
  • 4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control
  • 4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control
  • 4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control
4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control

4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control

Product Details:

Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE/NSF etc.
Model Number: SWRO-250~9000LPH,5-10

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Export Wood Crate/Carton or Naked wrapped by film
Delivery Time: 15~30 days
Payment Terms: T/T, Western Union, Paypal etc.
Supply Ability: 50 set per month
Get Best Price Contact Now

Detail Information

Technology: Reverse Osmosis Design: Skid Mount
Recovery Rate: 8~40% Feed TDS/ppm: <42,000
Water Temp.: 5~35˚C PH: 4~9
Dissolved Iron Mg/L: <0.1 Material: SS304/SS316L,carbon Steel
Voltage: 380V,415V,220V,can Be Customized Application: Water Purification,Filtration,pharmceutical,drinking Water,food
Function: Water Purifying, Desalination Control: Electronic,Manual/PLC
Ro Membrane: Hydranautics Or DOW,4040 Pump: Danfoss/CAT/CNP
High Light:

4000LPD Reverse Osmosis Desalination System

,

4.0KW/H Seawater Reverse Osmosis

,

4000LPD Seawater Reverse Osmosis

Product Description

4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control

Compact 4.0KW/H 4000LPD Seawater Reverse Osmosis System

Reverse Osmosis Sea Water Purification System Seawater Desalination Plant 300~6000GPD

4000lpd seawater desalination equipment:

 

1. Capacity: 4000L/D
2. Rated power: 4.0KW/H
3. Voltage: 110V/220V/380V, 50Hz/60Hz, single phase/3phase
4. Desalting rate:>=98%
5. Water recovery rate: 30-35%
6. TDS of raw water: ≤35000PPM
7. TDS of pure water: ≤750PPM

 

Seawater Desalination System Features:

* The design of the entire reverse osmosis seawater desalination control system is controlled by advanced computer programs at home and abroad, and a distributed sampling control and centralized monitoring operation control system is formed by the programmable controller PLC of the industrial computer operating station.
* Set high and low pressure protection switches and automatic switching devices according to process parameters. When abnormal conductance, flow and pressure occur, automatic switching, automatic interlocking alarm, and shutdown can be realized to protect high-pressure pumps and reverse osmosis membrane elements.
* Frequency conversion controls the start and stop of the high-pressure pump, realizes the soft operation of the high-pressure pump, saves energy consumption, and prevents damage to the high-pressure pump and membrane elements due to water hammer or back pressure. The program is designed to realize low-pressure automatic flushing before and after the reverse osmosis device is turned on and off.
* Especially during shutdown, the meta-stable state of concentrated seawater will transform to precipitate and pollute the membrane surface. Automatic flushing of low-pressure desalinated water can replace concentrated seawater for protection. The film surface is not contaminated, which extends the life of the film.
* The temperature, flow, water quality, output and other related parameters of the system can be displayed, stored, counted, tabulated and printed. The dynamic process flow screen in the monitoring operation is clear and intuitive, and the system control simplifies manual operations to ensure that the system can run automatically, safely and reliably.

 

Seawater Desalination Equipment Capacity

 

Model Capacity Recovery Rate Desalination Output power Membrane Brand SWRO Rack Size (mm)
SWRO-250 250L/H 50% 97% 1.5kw USA-DOW 1550*620*1670
SWRO-500 500L/H 50% 97% 1.5kw USA-DOW 1650*630*1800
SWRO-750 750L/H 50% 97% 2.5kw USA-DOW 1870*630*1850
SWRO-1000 1000L/H 50% 97% 2.5kw USA-DOW 1870*650*1850
SWRO-1500 1500L/H 50% 97% 3.0kw USA-DOW 2440*750*2000
SWRO-2000 2000L/H 50% 97% 3.5kw USA-DOW 2440*650*1750
SWRO-3000 3000L/H 50% 97% 4.0kw USA-DOW 2440*620*1850
SWRO-4000 4000L/H 50% 97% 5.0kw USA-DOW 2000*900*1800
SWRO-5000 5000L/H 50% 97% 7.5kw USA-DOW 2000*900*1800
SWRO-6000 6000L/H 60% 97% 9.5kw USA-DOW 3000*900*1800
SWRO-8000 8000L/H 60% 97% 13.5kw USA-DOW 3000*900*1800
SWRO-9000 9000L/H 60% 97% 14.0kw USA-DOW 3000*900*1800


Seawater Desalination Equipment Performance:

*Auto controller, RO membrane auto flush to protect membrane.
*Auto start when pure water tank have no water.
*Low pressure protection switch to protect high pressure pump when there is no raw water.
*High efficient and low noise high pressure pump.
*Product water conductivity meter to monitor product water quality all the time.
*Input water and output water pressure gauge to monitor RO membrane *differential pressure to remind it's time for chemical cleaning.
*Inlet water solenoid valve to stop water when machine is stop.

Seawater Desalination Equipment Component:

There are several kinds of consumables you need to replace regularly. (for 500LPH)
a. Quartz sand: replaced about every 15 months. 50kg/bag,100kg/set
b. Activated carbon: replaced about every 15 months. 25kg/bag, 25kg/set
c. Resin: replaced about every 15 months. 25L/bag, 50L/set


Seawater Desalination Equipment Processing

Process: raw water tank + raw water pump + quartz sand filter + activated carbon filter + water softener/chemical dosing system(optional) + security filter + high pressure pump + ro system + pure water tank + UV sterilizer(ozone generator) + precision filter + water supply point

 

Some parts function:

1. Raw water pump: provide needed pressure for every pre-treatment filter;
2. Quartz sand filter: use fiber glass as housing, fill quartz sand, it can filter big particles impurities, suspended substances, colloids etc. Important to remove iron and sediments you mentioned;^^
3. Activated carbon filter: use fiber glass as housing, fill activated carbon, remove color, odor, residual chlorine and organics substances;
4. Security filter: prevent large particles, bacteria, viruses into RO membrane, accuracy is 5µm;
5. High pressure pump: provide needed working pressure for RO system, ensure production capacity of pure water;
6. RO system: can remove particles, colloids, organic impurities, heavy metal ions, bacteria, virus, heat source etc. harmful substances and 99% dissolved salts.
7. Ozone generator(for bottled drinking): can continue to kill bacteria even water fill into bottled,viruses,cell damage,atc...

 

 

4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control 04.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control 1

Want to Know more details about this product
I am interested in 4.0KW/H 4000LPD Seawater Reverse Osmosis PLC Control could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.