• Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water
  • Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water
  • Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water
  • Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water
Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water

Product Details:

Place of Origin: China
Brand Name: Fenigal/OEM
Certification: CE etc.
Model Number: SF-1200

Payment & Shipping Terms:

Minimum Order Quantity: 1 Set
Price: Negotiable
Packaging Details: Standard Export Wood Crate/Carton or Naked wrapped by film/Containerized
Delivery Time: 15~30 days
Payment Terms: T/T, Western Union, Paypal etc.
Supply Ability: 200 set per month
Get Best Price Contact Now

Detail Information

Technology: Pressurized Filtration Material: Carbon Steel
Design: Skid Mount/containerized Water Temp.: 5~35˚C
Water Flow Rate: Up To 2~100 M3/H.vessel Voltage: 380V,415V,220V,can Be Customized
Application: Surface, Underground Water, Sewage Water Treatment Size: Dia.50cm~320cm
High Light:

bypass automatic backwash sand filter

,

bypass automatic backwash filter

,

industrial water automatic backwash sand filter

Product Description

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water

Automatic Backwash Bypass Sand Filter in Cooling Tower Circulating Industrial Water

Automatic Backwash by Pass Sand Filter in Cooling Tower Circulating Industrial Water


By-pass filter for chilled water as a by-pass filtering equipment of closed industrial circulating water is used to filter the circulating chilled water and its control modes consist of manual backwash and automatic backwash. The system is generally backwashed once every three to seven days in the circulating process, effectively improving the quality of chilled water and ensuring excellent and stable water quality after intervention to long-term running. The device has small water consumption and is widely used in the cleaning of all types of industrial and commercial chilled water circulation system as well as refrigerant water and heat medium water systems of central air conditioning, improving the stability of equipment operation. Users may weld and conned in parallel the by-pass filters in main return pipes depending on the conditions of circulation system and the pipe diameter should be determined based on the retaining water yield of parallel circulating water. The sewage water is then discharged into the sewerage network.

 

Working principle
For the by-pass filtration, the filter is installed in the main circulating pipeline to filter all the circulating water, but a part of the circulating water LED from the main circulating pipeline is filtered, which is a repeated circulating interception step by step to filter the impurities within the system and finally remove the impurities by the necessary backwash out of the system. Installing a by-pass filter in the circulating water system can prevent the terminal pipe of device from sludge blocking and remove the impurities in the system with chemical dosing.
By-pass filtration is used to reduce the turbidity of the water circulation system, exactly, to reduce slime and prevent its deposition in the heat exchanger, so that the effect of agent will be better.

Generally speaking, if your filter is a quartz sand filter, it usually has two main functions:
1. To reduce suspended solids (turbidity). Otherwise, as the system is running, suspended solids increases, which will exacerbate the deposition and other problems.
2. Degreasing. Especially the oily turbid circulation, such as steel rolling and continuous casting, has high oil content and is easy for breeding microorganism and blocking the nozzles.

Technical description of by-pass filter for the industrial circulating water
Flow filter flow is designed according to 5% to 10% of the total circulation volume (the by-pass filter flow of the cooling water is designed by 10 % of the circulation volume and the by-pass filter flow of chilled water is designed by 5% of the circulation volume) and the filtration rate is designed by 20 - 3Smih according to water quality of the system. Specific to corrosive suspended solids of the circulating water system as well as the control, our technical support team has designed a variety of manual/automatic by-pass filtrating equipment in line with customer demand.

 

The characteristics of the filtration system
1. Manual or automatic control is available;
2. Water distributor is simple, uniform and reliable;
3. Finished water collector has high strength and long service life;
4. Easy to install. Only connect the inlet and outlet to the waste pipe when installing;
5. Less water consumption in backwash: A homogeneous filter is used, so that backwash cycle is extended and the total backwash water volume is greatly reduced;
6. High backwash efficiency: An advanced water collector is used, ensuring efficient backwash effect.

 

 

The size of each filter, the number of filters required, and the type of filter media used depend upon:

1. What is the capacity(gpm or m3/h)do you require?

2. What is the raw water?

3. What is the power supply in your country?

---Is it 220-240V,50/60Hz,1 phase or other standard?

4. What will the be treated warter used for?

model Filter diameter Height inlet-outlet Filtration area capacity
mm mm mm m³/hour
SF-500 500 816 40 0.2 6~10
SF-600 600 874 40 0.28 8~14
SF-700 700 900 40 0.38 12~19
SF-800 800 960 DN50 0.50 15-25
SF-1000 1000 1200 DN50 0.79 23-39
SF-1200 1200 1400 DN80 1.13 33-55
SF-1400 1400 1600 DN100 1.54 45-75
SF-1600 1600 1800 DN100 2.01 60-100
SF-1800 1800 1950 DN150 2.54 75-125
SF-2000 2000 2150 DN150 3.14 95-155
SF-2200 2200 2250 DN150 3.80 115-190
SF-2400 2400 2100 DN150 4.52 130-210
SF-2600 2600 2400 DN150 5.30 145-225
SF-2800 2800 2500 DN200 6.15 155-240
SF-3000 3000 2600 DN200 7.00 170-255
SF-3200 3200 2800 DN250 8.15 270-320

 

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water 0

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water 1

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water 2

Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water 3

Want to Know more details about this product
I am interested in Bypass Automatic Backwash Sand Filter In Cooling Tower Circulating Industrial Water could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.